Commercial RO System with 3000-6000 GPD FRP Tank & UV |
|
  |
Feed Water Parameters:- Max. temperature 85oF.
- Max. pressure between 40~80 psi.
- Max. TDS 2,000 PPM.
- Max. Iron tolerance 0.5 PPM.
- Hydrogen sulfide must be removed.
- Silica tolerance can not be higher than 125 PPM in the concentrate stream. Anticipant should be considered for any over 75 PPM.
- Turbidity should be removed.
- Hardness must be removed.
Operating Parameters:- Max. operating pressure 200psi.
- Water recovery up to 60% but not recommended to adjust higher than 50%.
- PH range 3-11.
- Flow rates are determined by the membrane mfg's testing criteria of 1,500 PPM NACl solution, 77F water temperature, 225psi at 10~15% recovery. Actual flow rates may vary depending on the pretreatment, water conditions, system volume, membrane array and operation pressure.
|
 |
|
|